Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central

Willem J. Verberk, Hao‐Min Cheng, Li-Chih Huang, Chia-Ming Lin, Yao-Pin Teng, Chen‐Huan Chen

PULSE · 2015-yil

Annotatsiya

Accumulating evidence indicates that central blood pressure (CBP) is a better cardiovascular risk predictor than brachial blood pressure (BP). Although more additional benefits of CBP-based treatment above usual hypertension treatment are to be demonstrated, the demand for implementing CBP assessment in general clinical practice is increasing. For this, the measurement procedure must be noninvasive, easy to perform, and cost- and time-efficient. Therefore, oscillometric devices with the possibility to assess CBP seem the best option. Recently, such an oscillometric BP monitor, the Microlife WatchBP Office Central, was developed, which demonstrated its high accuracy in a validation study against invasive BP measurement. Calibration errors of this device are limited because the procedure is automated, standardized, and performed at the same place of and within 30 s from pulse wave assessment. The transformation from the peripheral pulse wave to CBP is done by means of an individual-based pulse wave analysis according to a theory of arterial compliance and wave reflections. In addition, the device has demonstrated to enable a more reliable diagnosis of hypertension by CBP than by peripheral BP, with a lower frequency of over- and underdiagnosis. Altogether, the available clinical evidence suggests that the Microlife WatchBP Office Central fulfills the criteria for general clinical use.

Maqola ma’lumotlari
MualliflarWillem J. Verberk, Hao‐Min Cheng, Li-Chih Huang, Chia-Ming Lin, Yao-Pin Teng, Chen‐Huan Chen
JurnalPULSE
NashriyotPROFI университетининг
ISSN2074-1855, 2235-8668
Nashr sanasi2015-01-01
Jild3
Son3-4
Betlar205-216
TilIngliz
Ilmiy sohaPsixologiya
DOI10.1159/000443771
Indeksga qo‘shilgan2026-09-02

Ilmiy soha

Iqtibos keltirish

APAWillem J. Verberk, Hao‐Min Cheng, Li-Chih Huang, Chia-Ming Lin, Yao-Pin Teng, & Chen‐Huan Chen (2015). Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central. PULSE, 3(3-4), 205-216. https://doi.org/10.1159/000443771
GOST (OAK)Willem J. Verberk va b. Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central // PULSE. – 2015. – T. 3, № 3-4. – P. 205-216. – DOI: 10.1159/000443771.
MLAWillem J. Verberk, Hao‐Min Cheng, Li-Chih Huang, Chia-Ming Lin, Yao-Pin Teng, and Chen‐Huan Chen. “Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central.” PULSE, 3(3-4), 205-216, 2015. https://doi.org/10.1159/000443771
ChicagoWillem J. Verberk, Hao‐Min Cheng, Li-Chih Huang, Chia-Ming Lin, Yao-Pin Teng, and Chen‐Huan Chen. “Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central.” PULSE, 3(3-4), 205-216 (2015). https://doi.org/10.1159/000443771
HarvardWillem J. Verberk, Hao‐Min Cheng, Li-Chih Huang, Chia-Ming Lin, Yao-Pin Teng, and Chen‐Huan Chen (2015) ‘Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central’, PULSE, 3(3-4), 205-216. https://doi.org/10.1159/000443771
BibTeX
@article{willemjverberk2015,
  title = {Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central},
  author = {Willem J. Verberk and Hao‐Min Cheng and Li-Chih Huang and Chia-Ming Lin and Yao-Pin Teng and Chen‐Huan Chen},
  journal = {PULSE},
  year = {2015},
  volume = {3},
  number = {3-4},
  pages = {205-216},
  doi = {10.1159/000443771},
  url = {https://doi.org/10.1159/000443771}
}

Boshqa maqola uchun iqtibos tayyorlash

PULSE jurnalidan boshqa maqolalar

PULSE — barcha maqolalar · 2015-yil arxivi

Psixologiya sohasidagi boshqa maqolalar

Psixologiya sohasidagi OAK jurnallari