Background: the continuity of traction power supply on electrified railways depends directly on the technical condition of overhead contact line components. Deviation of a supporting cantilever from its prescribed angular position degrades pantograph–contact wire interaction and increases the risk of component damage and unplanned supply interruptions. Because such changes remain unobserved between periodic inspections, primary transducers for automatic monitoring of cantilever angular displacement are required. Aim: to develop electromagnetic transducers for automatic monitoring of catenary cantilever angular displacement, to compare their technical and metrological characteristics with those of an existing transducer, and to estimate the economic effect of their application on an operating catenary section. Methods: the theory of electromagnetic induction and mutual inductive coupling, experimental determination and comparative analysis of static conversion characteristics, evaluation of metrological parameters (sensitivity, full-scale error, non-linearity), and an economic-effect calculation based on operating costs were applied. Results: the proposed ET-1 and ET-2 transducers provide a sensitivity of 0.020 V/degree, four times that of the existing transducer (0.005 V/degree). The measurement error was reduced from 2.0% to 1.5% and 1.0%, respectively. In ET-2, with the 0–90° measuring range retained, the non-linearity of the static characteristic decreased from 2.5% to 0.1% and the mass from 1.2 to 0.6 kg. The transducer was installed on an operating catenary section; under the adopted operating data, the estimated economic effect for the first year of implementation amounts to UZS 107,548,000.
| Mualliflar | Sulton F. Amirov, Javhar S. Fayzullayev |
|---|---|
| Jurnal | Энергия ва ресурс тежаш муаммолари |
| Nashriyot | «Ўзбекэнерго» АО, ТДТУ, Ўзбекистон Республикаси ФА, Энергия ва ресурслар тежаш илмий-амалий ўқув маркази, «Ўздавэнергоназорат» давлат инспекцияси, «Энергия тежамкорлиги ва қайта тикланувчи энергия манбалари» илмий-тадқиқот лабораторияси |
| ISSN | 2091-5985, 2181-1946 |
| Nashr sanasi | 2026-10-19 |
| Son | 3 |
| Betlar | 16-28 |
| Til | Ingliz |
| Ilmiy soha | Texnika |
| Indeksga qo‘shilgan | 2026-10-22 |
контактная сеть, overhead contact line, kontakt tarmog‘i
| APA | Sulton F. Amirov, & Javhar S. Fayzullayev (2026). Automatic monitoring of the angular displacement of catenary cantilevers: improving the reliability of railway traction power supply based on electromagnetic transducers. Энергия ва ресурс тежаш муаммолари, (3), 16-28. https://energy.tdtu.uz/index.php/journal/article/view/444 |
|---|---|
| GOST (OAK) | Sulton F. Amirov, Javhar S. Fayzullayev Automatic monitoring of the angular displacement of catenary cantilevers: improving the reliability of railway traction power supply based on electromagnetic transducers // Энергия ва ресурс тежаш муаммолари. – 2026. – № 3. – P. 16-28. |
| MLA | Sulton F. Amirov, and Javhar S. Fayzullayev. “Automatic monitoring of the angular displacement of catenary cantilevers: improving the reliability of railway traction power supply based on electromagnetic transducers.” Энергия ва ресурс тежаш муаммолари, (3), 16-28, 2026. https://energy.tdtu.uz/index.php/journal/article/view/444 |
| Chicago | Sulton F. Amirov, and Javhar S. Fayzullayev. “Automatic monitoring of the angular displacement of catenary cantilevers: improving the reliability of railway traction power supply based on electromagnetic transducers.” Энергия ва ресурс тежаш муаммолари, (3), 16-28 (2026). https://energy.tdtu.uz/index.php/journal/article/view/444 |
| Harvard | Sulton F. Amirov, and Javhar S. Fayzullayev (2026) ‘Automatic monitoring of the angular displacement of catenary cantilevers: improving the reliability of railway traction power supply based on electromagnetic transducers’, Энергия ва ресурс тежаш муаммолари, (3), 16-28. https://energy.tdtu.uz/index.php/journal/article/view/444 |
| BibTeX | @article{sultonfamirov2026,
title = {Automatic monitoring of the angular displacement of catenary cantilevers: improving the reliability of railway traction power supply based on electromagnetic transducers},
author = {Sulton F. Amirov and Javhar S. Fayzullayev},
journal = {Энергия ва ресурс тежаш муаммолари},
year = {2026},
number = {3},
pages = {16-28},
url = {https://energy.tdtu.uz/index.php/journal/article/view/444}
} |
Boshqa maqola uchun iqtibos tayyorlash
Relevance: synchronous turbo generators are one of the main electro-technological devices for generating electricity in the power supply system, and their stable and reliable operation is important for ensuring the…
Relevance: This article is devoted to the analysis of the structural and operational characteristics of power transformers used in railway power supply systems. The main components of transformers — magnetic core…
Relevance: operational data from distribution networks contain noise, outliers and locally heterogeneous operating regimes that may distort neural-network training and reduce forecast robustness. This creates a need for…
Relevance: Heat transfer in an LED lighting device depends on its construction, material properties and operating conditions. An average temperature estimate cannot fully identify local hot spots on the LED board…
Relevance: The rapid growth in electricity consumption across all areas of modern human activity, the limited reserves of hydrocarbon fuels, and the growing urgency of environmental problems in the energy sector…
Relevance: Uneven allocation of single-phase consumers in low-voltage urban networks causes phase-current unbalance, increased fundamental-frequency neutral current, unequal bus voltages and additional conductor losses…
Relevance: improving two-speed induction motors is an important task for electric drives used in machinery whose operating processes require two fixed rotational speeds. Separate stator windings limit slot-space…
Relevance: The energy efficiency of air-cooled heat exchangers directly depends on the structural characteristics of the heat-transfer surface, tube arrangement, degree of finning, organization of the air flow, and the…
Relevance: At present, the efficient and rational use of electrical energy in industrial enterprises, reduction of energy consumption, and improvement of the energy efficiency of production processes are among the…
Relevance: this article is devoted to assessing the technological factors affecting specific electricity consumption in the ore grinding process at mining enterprises. Variations in electricity consumption during ore…
Энергия ва ресурс тежаш муаммолари — barcha maqolalar · 2026-yil arxivi
This article examines compression as a meaning-oriented strategy in sign language translation and interpreting. Compression is understood not as arbitrary shortening, but as the selective reformulation of a source…
This study investigates the impact of Edge Computing on bandwidth utilization in Internet of Things (IoT)–driven Nigerian telecom networks. The rapid growth of IoT devices has significantly increased data traffic…
This article analyzes the scientific, pedagogical, and methodological foundations for the effective integration of national upbringing factors with modern global competencies in the context of continuous education…
This article addresses the problem of improving an adaptive traffic signal control algorithm at urban intersections by taking into account the dynamic characteristics of traffic flow. Fixed-time control under conditions…
Maqolada paxta xomashyosini yirik iflosliklardan tozalash jarayonida arrali baraban va kolosnikli panjara o‘rtasidagi o‘zaro ta’sirni takomillashtirish masalasi ko‘rib chiqilgan. Mavjud tozalagichlarda qo‘llaniladigan…
Maqolada paxta xomashyosini yirik va mayda iflosliklardan tozalash samaradorligini oshirishga qaratilgan ilmiy tadqiqotlar tizimlashtirilib, konstruktiv va texnologik omillarning o‘zaro ta’siri qiyosiy tahlil qilindi…