TEST OF EXPERIMENTAL ULTRAFILTRATION INSTALLATION

X Isaxodjayev, L. Ya. Alimova, B Boliyev

Тошкент давлат техника университети хабарлари · 2020-yil

Annotatsiya

The paper presents the test results of an ultrafiltration unit. During the test, one of the main parameters of the ultrafiltration process, membrane permeability and a rational process parameter, a linear velocity in the range of 4-7 s/m . According to the results, it can be determined that the process is considered effective if the membrane permeability remains maximum for a long time at a given selectivity and with minimal energy consumption. It was found that for ultrafiltration separation of concentrated solutions of iron hydroxide, the optimal values of the linear velocity are in the range of 5.0-10.0 s/m at an overpressure of 0.6-1.2 MPa.

Maqola ma’lumotlari
MualliflarX Isaxodjayev, L. Ya. Alimova, B Boliyev
JurnalТошкент давлат техника университети хабарлари
Nashr sanasi2020-09-30
Jild2020
Son3
Betlar153-158
Tilen
DOI10.51346/tstu-01.20.3-77-0074

Тошкент давлат техника университети хабарлари jurnalidan boshqa maqolalar

Тошкент давлат техника университети хабарлари — barcha maqolalar